SECTION II: GENERAL INFORMATION
This instruction covers the installation of the following coils with 80+ or
90+ AFUE furnaces or MA/MX/MV air moving systems.
The coils have sweat connect fittings. All coils are shipped with a low
psi nitrogen holding charge.
Coil Access
Panel
Suction Line
Connection
Liquid Line
Connection
Primary Drain
Secondary Drain
Bottom Door Panel
FIGURE 1: Component Location - Coil MC & FC
INSPECTION
As soon as a coil is received, it should be inspected for possible dam-
age during transit. If damage is evident, the extent of the damage
should be noted on the carrier's delivery receipt. A separate request for
inspection by the carrier's agent should be made in writing. See Local
Distributor for more information. Check drain pan for cracks or break-
age.
TABLE 1: Dimensions - MC Coils
-
20 3/8"
(Opening)
B
BOTTOM OPENING
DIMENSIONS
D
1. All dimensions are in inches.
2. Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077.
2
Label
Location
Drain Location
Horizontal Application
(on MC Coils Only)
Alternate Drain Location
C
A
21 1/2"
-
-
20 1/4"
Suction Line
Connection
Liquid Line
Connection
Coil Access
Panel
Primary Drain
Secondary Drain
Bottom Door Panel
FIGURE 2: Component Location - Coil PC
CLEARANCES
DURING INSTALLATION
Clearance must be provided for:
1. Refrigerant piping and connections
2. Maintenance and servicing access - including cleaning the coil
3. Condensate drain line
4. Filter removal / change
5. Removal of coil assembly
Dimensions
Models
Height
Width
A
B
MC18A
22
14-1/2
MC18B
22
17-1/2
MC24A
26-1/2
14-1/2
MC24B
26-1/2
17-1/2
MC30A
26-1/2
14-1/2
MC30B
26-1/2
17-1/2
MC32A
22
14-1/2
MC35B
22
17-1/2
MC35C
22
21
MC36A
26-1/2
14-1/2
MC36B
26-1/2
17-1/2
MC36C
26-1/2
21
MC37A
26-1/2
14-1/2
MC42B
32
17-1/2
MC42C
32
21
MC43B
26-1/2
17-1/2
MC43C
26-1/2
21
MC48C
32
21
MC48D
32
24-1/2
MC60D
32
24-1/2
MC62D
36
24-1/2
Label Location
Alternate Drain Locations
Refrigerant
1
Connections
Opening Widths
Line Size
C
D
Liquid
13-3/8
13-1/2
16-3/8
16-1/2
13-3/8
13-1/2
16-3/8
16-1/2
13-3/8
13-1/2
16-3/8
16-1/2
13-3/8
13-1/2
16-3/8
16-1/2
19-7/8
20
13-3/8
13-1/2
16-3/8
16-1/2
3/8
19-7/8
20
13-3/8
13-1/2
16-3/8
16-1/2
19-7/8
20
16-3/8
16-1/2
19-7/8
20
19-7/8
20
23-3/8
23-1/2
23-3/8
23-1/2
23-/8
23-1/2
2
Vapor
3/4
7/8
3/4
7/8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents