2.
Basic Operation
Using the Setting Change Switches
Using the Setting Change Switches
This section explains how to use the setting change switches of the controller enclosure.
The following settings can be performed by using the setting change switches:
Switching the Master CM to the other controller
•
For the two controllers in the ETERNUS DX, the controller through which the ETERNUS DX is set up and oper-
ated is called the "Master CM", while the other controller is called the "Slave CM".
Restoring the factory default settings (network environment settings and firewall settings) of the LAN ports
•
•
Restoring the factory default user settings (user account, role, and RADIUS settings)
The operating procedure for the setting change switches is described below.
1
Remove the flange cover and the front cover of the controller enclosure.
Flange cover
2
Change the status of the ETERNUS DX to maintenance status.
Use the pin to push down the MNT SW (maintenance switch) for three seconds.
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Operation Guide (Basic)
Front cover
58
Copyright 2018 FUJITSU LIMITED
P3AM-7742-12ENZ0