Basic Operation
Powering On and Off
For the ETERNUS DX500 S4 and the ETERNUS DX500 S3/DX600 S3, it takes approximately five minutes (or
approximately 10 minutes for a Unified configuration and approximately 20 minutes for a VLAN/Bonding
maximum configuration) to reach the READY state (the READY LED turns on) after the ETERNUS DX is
turned on. If an error is detected in a component during the initial power-on diagnostics, it may take a
maximum of 10 minutes (or a maximum of 11 minutes for a configuration in which the Deduplication/
Compression function is enabled, approximately 40 minutes for a Unified configuration, and approximately
50 minutes for a VLAN/Bonding maximum configuration) for the ETERNUS DX to reach the READY state. If a
scheduled operation is being performed, make configurations by taking the operation into consideration.
For the ETERNUS DX600 S4, it takes approximately seven minutes (or approximately 12 minutes for a Uni-
fied configuration and approximately 22 minutes for a VLAN/Bonding maximum configuration) to reach the
READY state (the READY LED turns on) after the ETERNUS DX is turned on. If an error is detected in a compo-
nent during the initial power-on diagnostics, it may take a maximum of 12 minutes (or a maximum of 18
minutes for a configuration in which the Deduplication/Compression function is enabled, approximately 42
minutes for a Unified configuration, and approximately 52 minutes for a VLAN/Bonding maximum configu-
ration) for the ETERNUS DX to reach the READY state. If a scheduled operation is being performed, make
configurations by taking the operation into consideration.
Before turning the server on, check that the ETERNUS DX and the network devices that connect the ETER-
NUS DX and the server are all in READY status.
If the server is turned on while any of these devices are not in READY status, the server may not be able to
recognize the ETERNUS DX.
To turn on the ETERNUS DX by linking with the server, the server must wait until the ETERNUS DX is in the
READY state.
If the Auto Power function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is automatical-
ly turned on when power is supplied to the ETERNUS DX.
If the Power Resume function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is automat-
ically turned on after the power is restored.
If the REMOTE LED of the ETERNUS DX is green, turn on the ETERNUS DX via a power synchronized unit.
After power-off, wait for about one minute before turning power on again.
If the ETERNUS DX is not turned off normally due to problems such as a power failure, it takes approximate-
ly 10 minutes (max.) longer to reach the READY state the next time the ETERNUS DX is turned on.
This section explains how to use the Power switch to turn on the ETERNUS DX.
For other procedures, refer to the related manuals.
1
Press the Power switch of the controller enclosure.
Power switch
The POWER LEDs on the controller enclosure and the drive enclosures are turned on.
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Operation Guide (Basic)
Controller enclosure
55
Copyright 2018 FUJITSU LIMITED
P3AM-7742-12ENZ0