Fast Flush

To flush the hose and gun at an accelerated speed, per-
form the following steps:
1. Perform steps 1 - 3 of Cleanup, page 18.
2. Squeeze gun trigger and turn prime valve down to
DRAIN position and then over to FAST FLUSH.
3. Continue flushing system until fluid appears clear.
3A4399A
ti22940a
WatchDog
System
Pump stops automatically when material pail is empty.
To Activate:
1. Perform Startup.
2. Turn WatchDog switch ON and WD ON displays.
EMPTY displays/flashes and pump stops when
Watchdog protection system detects an empty
material pail.
3. Turn WatchDog switch OFF. Add material or rep-
rime sprayer. Turn pump switch OFF and ON to
reset WatchDog protection system. Turn WatchDog
switch back ON to continue to monitor material
level.