2.1 Changed and Added Features
Extension – Day / Night> This assigns the DISA line and the message accessed by
external callers.
c)
The DISA message(s) should be recorded by the operator.
• Only one DISA Unit (for KX-TD816) or DISA Card (for KX-TD1232) can be installed per
system. During System Connection
used in the same system.
• A DISA call is answered after a ringback tone is returned to the caller after the DISA
Delayed Answer Time expires. <[213] DISA Delayed Answer Time> The caller can dial
during the message.
• The floating number of a DISA message may be selected as the destination of Intercept
Routing. <[409-410] Intercept Extension – Day / Night>
• DISA Built-in Automated Attendant:
This system can store up to ten programmable DISA built-in automated attendant numbers.
<[818] DISA Built-in Automated Attendant Number> After listening to the DISA message,
the caller can dial a single digit. The number may be the same as the first digit of other
numbers (extension number, floating number, etc.). To avoid confusion, the system waits
for the second digit for a preprogrammed amount of time (default: 1 second). If the timer
runs out of time, the system assumes that the first digit is a DISA built-in automated
attendant number. <[221] DISA AA Wait Time>
• The DISA line can be used to originate outside calls if a security code (if required) has been
dialled.
• This system can store up to 32 programmable DISA user codes. Each code should be
unique. It is possible to assign a Class of Service number to each code. The Class of Service
of the code defines the Toll Restriction level. <[016] DISA / TIE User Codes / [811] DISA
/ TIE User Codes>
• The duration of outside-to-outside line calls can be limited. <[206] Outside-to-Outside Line
Call Duration Time> When the specified time expires, both lines are disconnected unless
the caller re-tries or extends the time, if available. A warning tone is sent to both parties 15
seconds before the time-limit at five-second intervals.
• Extending the call duration can be enabled from one to seven minutes or disabled. <[214]
DISA Prolong Time> The caller can do this several times.
• To detect the end of an outside-to-outside line call, Calling Party Control (CPC) Signal
Detection and Tone Detection can be assigned. <[405] CPC Signal Detection Incoming Set,
[415] CPC Signal Detection Outgoing Set, [810] DISA Tone Detection>. And the system
can detect the type of tone (Continuous/Cycled/No Tone). <[990] System Additional
Information, Area 09-Bits 1-3>.
• Dialling " " during DISA outside-to-outside line conversation enables or disables the call
retry. If disables, " " will simply be dialled. <[990] System Additional Information, Area
07-Bit 10>
• When you dial the wrong DISA user code 3 times, your call will be disconnected.
• When a DISA call arrives at a busy extension which has disabled Call Waiting, a busy tone
will be sent to the caller. If required, Intercept Routing – No Answer (IRNA) can be
activated. <[990] System Additional Information, Area 07-Bit 7>