RF300 system planning
4.5 Installation guidelines
4.5.3

Effects of metal on different transponders and readers

Mounting different transponders and readers on metal or flush-mounting
Certain conditions have to be observed when mounting the transponders and readers on
metal or flush-mounting. For more information, please refer to the descriptions of the
individual transponders and readers in the relevant section.
4.5.4

Impact on the transmission window by metal

In general, the following points should be considered when mounting RFID components:
● Direct mounting on metal is allowed only in the case of specially approved transponders.
● Flush-mounting of the components in metal reduces the field data; a test is
● When working inside the transmission window, it should be ensured that no metal rail (or
The impact of metal on the field data (S
The values in the table describe the reduction of the field data in % with reference to non-
metal (100% means no impact).
Reader RF310R:RF300 mode
Table 4- 18
Transponder
RF320T
RF340T
RF350T
RF360T
64
recommended in critical applications.
similar part) intersects the transmission field.
The metal rail would affect the field data.
Reduction of field data by metal (in %): Transponder and RF310R
Without metal
On metal; distance 20 mm
Flush-mounted in metal; distance
all-round 20 mm
Without metal
On metal
Flush-mounted in metal;
distance all-round 20 mm
Without metal
On metal
Flush-mounted in metal;
distance all-round 20 mm
Without metal
On metal; distance 20 mm
Flush-mounted in metal;
distance all-round 20 mm
, S
, L, B) is shown in tabular format in this section.
g
a
Without metal
100
100
80
100
80
70
100
70
60
100
100
60
System Manual, 01/2009, A5E01642529-03
RF310R reader
On metal
Flush-mounted
In metal
(20 mm all
around)
95
80
80
70
70
60
95
80
80
80
70
70
95
85
65
65
60
60
95
85
95
75
60
60
SIMATIC RF300