System overview

3.1

RFID systems

RFID systems from Siemens control and optimize material flow. They identify reliably,
quickly and economically, are insensitive to contamination and store data directly on the
product.
Identification
Frequency
system
RF300
13.56 MHz
MOBY D
13.56 MHz
MOBY E
13.56 MHz
MOBY I
1.81 MHz
SIMATIC RF300
System Manual, 01/2009, A5E01642529-03
Range,
Max.
max.
memory
0.15 m
20 byte
EEPROM,
64 KB
FRAM
0.8 m
112 byte
EEPROM
0,1 m
752 byte
EEPROM
0.15 m
32 KB
FRAM
Data transfer rate
Temperature,
(typical) in
max.
byte/s
RF300 tags: 8000
Readers:
-25 °C to +70 °C
ISO tags: 400/600
Transponder:
-40 °C to +85 °C
+220 °C cyclic
110
+ 85 °C or
+ 200 °C
350
+ 150 °C
1250
+ 85 °C or
+ 220 °C cyclic
3
Special features
IQ-Sense interface
available;
integrated diagnostic
functions;
battery-free data
memory;
additional ISO 15693
functionality
(RF310R/RF380R)
SmartLabels based on
ISO 15693
e.g. Tag-it/I-Code
Battery-free data
memory
Battery-free data
memory