Advertisement

Determine tolerance of pallet side transport
Figure 4-7
Minimum distance from reader to reader
Refer to the field data of the reader for this value.
Minimum distance from transponder to transponder
Refer to the field data of the transponder for this value.
Calculation of the maximum amount of user data in dynamic mode
Step
1.
Calculate dwell time of the
transponder
2.
Calculate maximum user data
(n
for reading or writing
max)
(FRAM area)
Result
A maximum of 172 bytes can be read or written when the transponder passes by.
SIMATIC RF300
System Manual, 01/2009, A5E01642529-03
Tolerance of pallet side transport
Formula/calculation
Refer to the "Field data of all transponders and readers" table for value L.
Value v
= 1.00 m/s
Tag
Take value t
from Step 1.
v
Take values K and t
Byte
4.1 Fundamentals of application planning
from Table "Time constants K and t
RF300 system planning
".
Byte
43

Advertisement