Factory Settings - Yamaha DME 32 Service Manual

Hide thumbs Also See for DME 32:
Table of Contents

Advertisement

DME32
WORD CLOCK
Permissible Range
44.1 kHz
5 nSec or less
48 kHz
5 nSec or less
3-3.
CASCADE IN/OUT Check
3-3-1. Connection
• Checks DME32 for one set of two units.
Both DME32 should have the latest version of the firmware loaded.
• Connect the [CASCADE IN] terminal for one unit with the
[CASCADE OUT] terminal for the outer unit with a SCSI 50p cable.
• Connect the [PC CONTROL] terminal and PC serial terminal
(Windows machine) with a D-sub 9P cross cable.
(First, connect as shown in "Connection 1" in the drawing below.)
Connection 1
DME32
PC
CASCADE OUT
Connection 2
DME32
PC
CASCADE OUT
Connection 3
DME32
PC
CASCADE OUT
3-3-2. Setting (Initialization)
• While pressing [RECALL], turn on the power switch.
(Continue to press until the LCD shown below is displayed.)
DIAGNOSTICS V1.0
RAM INITIAL.
*
• If the display shown above appears on the LCD, press [RECALL]
once again to initialize.
(The LCD will change to the display shown below)
DIAGNOSTICS V1.0
RAM INITIAL. END
• Turn the power supply switch off.
• Perform the operations shown above on both units.
3-3-3. Configuration transfer
• Turn on the power switches for the two units in sequence.
• The DME Manager from the PC (Windows machine) will start.
At this time, check if data is being received from DME32.
A message will appear. Click [No].
• Click [File] in the upper left hand corner of DME Manager and
select [Open] from the pull down menu.
• From the file selection menu, select the [CascadeCheck.dme]
file for checking Cascade Out and click [Open]. The
configuration for checking Cascade Out will be displayed.
• Click [File] in the upper left hand corner of DME Manager and
select [Data Transfer] from the pull down menu.
26
• Select Data Transfer Menu and then "A" from the list. The
LED ON Check
name will change in the title column. Click [Execute]. A
44.1 kHz/LOCK
confirmation message will be displayed. Click [OK].
48 kHz/LOCK
• It will automatically enter the run mode.
3-3-4. Check
• Double click "Meter 8" on the PC DME Manager and a detailed
display for Meter 8 will be displayed.
• Check that the meters in Meter 8 is oscillating.
DME32
• If all are OK, CASCADE OUT for DME32
IN for DME32
CASCADE IN
3-3-5. Changing the connections
<Connection 2>
• Changes the <Connection 1> shown in 3-3-1 to <Connection 2>.
DME32
• Perform the same operations as for connection 1 and 2.
CASCADE IN
• If OK, the CASCADE IN/OUT for DME32
DME32
<Connection 3>
• Changes <Connection2> to <Connection3>.
DME32
• Perform the same operations as for connection 1 and 2.
• If OK, the CASCADE IN/OUT for DME32
CASCADE IN
have passed.
4.
• PC CONTROL:
• WORD CLOCK IN 75Ω:
5.
• While pressing [RECALL], turn on the power switch.
(Continue to press until the LCD shown below is displayed.)
• If the display shown above appears on the LCD, press [RECALL]
once again to initialize.
(The LCD will change to the display shown below)
6.
• Perform operations (1) and (2) shown below in suitable
combinations. For either one, check that the LCD "momentarily
light" when the power supply switch is turned on and then end
the operation.
Regardless of the treatment, the input power supply voltage
should be AC100V.
(1) Turn the power switch ON-OFF approximately five times at
(2) Turn the power switch ON-OFF approximately five times at
Press the "1(~8)" button on the Run Mode Controller and then
press the "Recall" button. Scene 1 (~8) will be recalled.
When Scene 1 is recalled, the first meter for Meter8 will oscillate.
:
:
:
:
When Scene 8 is recalled, the eigth meter for Meter8 will oscillate.
have passed.
CASCADE IN has passed.

Factory settings

RS232C
ON
Initialization
DIAGNOSTICS V1.0
RAM INITIAL.
*
DIAGNOSTICS V1.0
RAM INITIAL. END
Start confirmation
fast intervals (approximately 1 second).
slow intervals (approximately 5 to 10 seconds).
and CASCADE
has passed.
and DME32