2.

WIRING

2.1

Wiring Outline

FAR-1513/1523
XN12A
XN13A
DISPLAY UNIT
12-24 VDC
MU-150HD /
MU-190
Analog RBG
Monitor
SWITCHING HUB
Radar
HUB-100
ECDIS
DC Spec.
24 VDC
100/110/115
200/220/230 VAC,
1ø, 50/60 Hz
AC Spec.
100/110/115
200/220/230 VAC,
1ø, 50/60 Hz
440 VAC,
1ø, 50/60 Hz
ANTENNA UNIT
FAR-1513
RW-00024
FAR-1523
RW-00025
(15/20/30 m)
DVI-D/D
S-LINK
(5/10 m)
3COX-2P-6C
(5/10 m)
FR-FTPC-CY
10/20/30 m)
MOD-Z072
(2/5/10 m)
100-230 VAC,
1ø, 50/60 Hz
PROCESSOR UNIT
DPYC-6
Rectifier
RU-1746B-2
RU-3424
DPYC-2.5
Stepdown
Transformer
Unit
RU-1803
ANTENNA UNIT
OR
FAR-1518/1528
RW-0030
(15/20/30 m)
TTYCSLA-4
TTYCSLA-1Q
TTYCSLA-4
TTYCSLA-1
TTYCSLA-1
TTYCSLA-4
TTYCSLA-4
TTYCSLA-7
RPU-024
RW-4864
(1/5/10 m)
RW-4864
(1/5/10 m)
CONTROL UNIT
RCU-028
FAR-1518
XN12AF
XN20AF
FAR-1528
XN20AF
XN24AF
CAUTION
Recommended maximum
length for signal cable is
30 m.
Use of signal cable with a
length of over 30 m can
degrade the radar's perfor-
mance.
AD-100
Heading sensor
AIS transponder
GPs navigator
Doppler log
AMS (serial)
ECDIS
AMS (contact)
Master
Sub display 1
Sub display 2
TRACKBALL
CONTROL UNIT
RCU-030
2-1

Advertisement

Table of Contents
loading

Table of Contents