Chapter 4 - Operation and Administration
The range of the Cell Number parameter is from 0 to 31. For Cells with 4 sectors
the range is from 0 to 17.
The default Cell Number is 0.
4.8.2.2.2.3
Cell Radius (m)
The maximum cell radius in meters. This is the distance from the BTS of the
farthest MS that it can serve.
The range is from 8000 to 40000 meter.
In the current release only Cell Radius values of 8000 and 40000 are supported.
The default Cell Radius is 40000 (m).
4.8.2.2.2.4
Map Repetition
The number of repetitions to use for transmitting DL MAP, UL Map, UCD (Uplink
Channel Descriptor), DCD (Downlink Channel Descriptor), and DIUC (Downlink
Interval Usage Code) messages.
The available values are 1, 2, 4.
The default value is 1.
4.8.2.2.3
PHY
The PHY submenu includes the following options:
Show: Select this option to view the relevant PHY parameters of the selected
BS. The displayed information is the same as described in the PHY section of
Show Summary (Section
Perform and Show UL Thermal Noise Measurement: Select this option to
perform uplink thermal noise measurement. The measurement is performed
by scheduling an empty uplink frame and extrapolating from the power
measured on this frame the average noise and interference (NI) level per
subcarrier. The measurement assumes that the NI level is constant across the
whole bandwidth, and it is performed on an empty uplink frame to avoid
taking into account the interference generated by the MS. The test takes about
one minute, and at the end the measured NI is displayed. The measured NI is
used for configuring the UL Thermal Noise Level parameter (see below). Note
that during the test the available throughput is affected because of the
allocation of empty uplink frames.
BreezeMAX Extreme
4.8.1).
140
BS Menu