Self-Diagnosis Function And Service Mode; Self-Diagnosis Function (Vtr Section) - Panasonic SA-HT833VP Service Manual

Dvd/vhs home theater sound system
Table of Contents

Advertisement

SA-HT833VP

10 Self-Diagnosis Function and Service Mode

10.1. Self-Diagnosis Function (VTR Section)

10.1.1. Sef-Diagnosis Display
(Overview)
The details of failures detected in circuit or mechanism by the microcomputer will be automatically displayed on the FL display
as the result of self diagnosis.
(Setting)
The details of a failure applicable to an error code are displayed on the minute, ten seconds, one second position of the FIP.
(Display)
FL display example:
(List of Remedy Code)
(List of Error Code)
Display
U11
U30
H01
H02
F03
F04
F05
F06
F07
F08
F15
H16
H17
H18
H80
F2*
Meaning
Detection of head clogging-ups
Remote controller mode error
No initialization of cylinder due to no loading(Cylinder, driving circuit
failure, etc.)
No capstan FG at load position(Capstan, driving circuit failure, etc.)
Mechanism locking not because of unloading, cassette up*
Displayed when detected twice consecutively.
Mechanism locking due to unloading* Displayed when detected twice
consecutively.
No S-reel pulse due to unloading(S-reel system, capstan system
failure)
Mechanism locking due to cassette up
Recording circuit operation failure during REC operation
Recording circuit operation failure not during REC operation
No capstan FG when cassette is loaded(Capstan system, S-reel
system failure)
Cylinder lock detected during normal rotation
S-reel lock detected during normal running
T-reel lock detected during normal running
EJECT mode when an error is detected
Error during PG automatic adjustment
Automatic
display
14
Memory
O
O
O
X
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
O
X
O
X
O
O
O
O
O
X
O
O
O

Hide quick links: