Wells WB-2 Supplemental Service Instructions page 8

Waffle bakers with electronic temperature control
Hide thumbs Also See for WB-2:
Table of Contents

Advertisement

SERVICING INSTRUCTIONS (continued)
CAUTION:
ELECTRIC SHOCK
HAZARD
Unplug appliance from
electric power before
removing any panel or
access cover.
SERVICE INSTRUCTION - COMPONENT REPLACEMENT
NOTES:
The drawings shows the right side top baking
assembly for a WB-2.
The left side assembly is similar, with the hinge
pivot components reversed.
The top baking assembly for a WB-1 is identical
to this drawing, with the exception of the conduit,
which is 90º, rather than the 45º conduit shown.
Insert small diameter end
P/N 55552 (90º for WB-1)
P/N 55547 (45º for WB-2)
Ground wire gets 4" of
FIBERGLASS SLEEVE
after it is pulled into casting
120V 450W P/N 507277
Assemble so that terminals
are at the 9:00 position
(when grid detail faces away,
and handle is at 6:00).
8-32 KEPS NUT 51053 (pk 100)
PLUG, TOP CASTING P/N 58628
Insert stud on clamping plate of Grid &
Element Assembly into hole of Casting &
Hinge Assembly. Ensure that grid gasket is
evenly seated. Secure assemblies with nut
and insert plug.
14
B. TOP GRID ASSEMBLY
WAFFLE BAKER TOP GRID ASSEMBLY
CASTING, TOP
1
P/N 50327
CONDUIT, CAST
P/N 50329
into hinge
2
SOLID CONDUIT
Power wires
Ground wire
6
P/N 54573 (rl 100ft)
ELEMENT, HEATING
10
3
4
5
HANDLE (ref.)
6
Pull power wires
through hinge to
this point
Pull ground wire
through hinge to
this point
PLUG,
HINGE PIVOT
P/N 50328
HINGE
P/N 50322
SCREW 8-32
P/N 51715 (pk 100)
Power wires get 9" of
7
RUBBERIZED SLEEVE
P/N 50284 (rl 10 ft) after
they are pulled into casting
8
GRID, UPPER P/N 58919
Be sure pattern of grids is
properly aligned.
GASKET, GRID P/N 50337
9
Check to insure gasket is
installed flush around casting
INSULATION PAD,
11
WB ELEMENT TOP
P/N 50430
Between clamp plate
and element
CLAMP PLATE, TOP
12
P/N 50431
SCREW, 8-32 x 5/16"
13
P/N 51715 (pk 100)
Do not tighten until all
screws are in place.
Trap ground wire under
this screw.
Ensure that
element terminals are
centered in opening of
clamping plate before
tightening screws.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wb-1

Table of Contents