E-8
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
Machine shuts off (input contactor
drops out) when the welder output
terminals are made electrically
"hot".
(#2 to #4 closure at terminal strip.)
or OUTPUT TERMINALS switch
is in ON position.
The DC600 will NOT shut off when
the Power Switch is turned to
OFF.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
POSSIBLE
CAUSE
OUTPUT PROBLEMS
1. Remove all welding cables and
control cables from the DC 600.
Jumper #2 to #4 at the terminal
strip or set OUTPUT TERMI-
NALS switch to ON position. If
the machine does NOT shut off
and normal open circuit voltage
is present at the welder output
terminals the problem is exter-
nal to the DC600. Either the
remote leads #75, #76 or #77
are grounded to the negative
output cable or there is a short
on the welding output terminals.
2. If the machine still shuts off
when all control and welding
cables are removed then the
problem is internal to the DC-
600.
1. Contact your local Lincoln
Authorized
Field
Facility.
CAUTION
IDEALARC® DC-600
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
Service
E-8