E-3
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
Major Physical or Electrical
Damage is Evident
The Machine is dead- The Input
contactor does not operate.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
POSSIBLE
CAUSE
OUTPUT PROBLEMS
Contact the Lincoln Electric Service
Dept. 1-(888)-953-3877.
1. Check for blown or missing
fuses in input lines.
2. Check the three- phase input
line voltage at the machine.
The input voltage must match
the rating plate and reconnect
panel.
3. Power ON/OFF switch may be
defective
CAUTION
IDEALARC® DC-600
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.