G. Fixed Glass Assembly
Removing Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
• DO NOT strike, slam or scratch glass.
• DO NOT operate fi replace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
• There are two glass latches securing the bottom of the
glass assembly.
• Release the latches by pulling forward and retracting
away from the glass assembly.
• Pull the bottom of the glass frame out and carefully lower
the glass until the two tabs at the top of the glass frame
clear the upper bracket.
Replacing Fixed Glass Assembly
• Place the two tabs at the top of the glass frame into the
location bracket.
• Pivot the bottom in and secure the bottom of the glass
frame with the two latches.
SURROUND LOCATING TABS
Figure 12.3 Fixed Glass Assembly
FIREBOX
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08
H. Air Shutter Setting
Air shutter settings should be adjusted by a qualifi ed in-
staller at the time of installation. The air shutter is set at
the factory for minimum vertical vent run. Adjust air shut-
ter for longer vertical runs.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Air Shutter Settings
QVI-35FB-S
NG
LP
Full Open
Full Open