Bosch LR 7 Professional Original Instructions Manual page 16

Hide thumbs Also See for LR 7 Professional:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
OBJ_BUCH-2651-002.book Page 16 Thursday, August 25, 2016 11:33 AM
16 | English
13 Type plate
14 Serial number
15 Battery lid
16 Latch of battery lid
17 Rotary knob of the universal holder
18 Guide rail
19 Holder latch
20 Pushbutton to release the lock
21 Holder* (1 608 M00 C1L)
*Accessories shown or described are not part of the standard delivery scope of the product.
A complete overview of accessories can be found in our accessories program.
Display Elements
a Battery low indicator
b Direction indicator "move downward"
c Centre indicator
d Direction indicator "move upward"
e Indicator for measuring accuracy "Coarse"
f Indicator for measuring accuracy "Fine"
g Audio signal indicator
Noise Information
The A-weighted sound pressure level of the audio signal at one meter distance
is 80 dB(A).
Do not hold the measuring tool close to your ear!
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the measuring tool.
Pull the latch 16 of battery lid outward and open the battery lid 15.
When inserting batteries, pay attention to the correct polarity according to the
representation on the inside of the battery compartment.
When the battery low indicator a appears for the first time on the display 6, the
measuring tool can still be operated for approx. 2 h.
 Remove the batteries from the measuring tool when not using it for extended
periods. When storing for extended periods, the batteries can corrode and self-dis-
charge.
1 609 92A 3G1 | (25.8.16)
Bosch Power Tools

Hide quick links: