Trouble Shooting - Ingersoll-Rand SSR UP6 15 Operation And Maintenance Manual

60hz
Hide thumbs Also See for SSR UP6 15:
Table of Contents

Advertisement

PROBLEM
CAUSE
Compressor fails to
Mains power or Control voltage not available.
start
Defective Star / Delta timer.
Machine shutsdown
High airend temperature.
periodically
periodically
Motor overload.
Belt stretch protection (when fitted).
Line voltage variation.
High current draw
Compressor operating above rated pressure.
Separator cartridge contaminated.
Low voltage.
Unbalanced voltage.
Damaged airend.
Low current draw
Air filter contaminated.
Compressor operating unloaded.
High voltage.
Defective inlet valve.
High discharge
Defective or incorrect pressure switch setting.
pressure
pressure
Load solenoid valve defective.
Blowdown valve defective.
Inlet valve malfunction.
Low system air
Separator cartridge contaminated.
pressure
pressure
Incorrect pressure switch setting.
Minimum pressure valve malfunction.
Load solenoid valve defective.
Blowdown valve defective.
Drive belt slipping.
Air system leaks.
Inlet valve malfunction.
System demand exceeds compressor delivery.
NOTES:
§
Must be carried out by a competent electrician.
This work is recommended to be carried out only by an Ingersoll–Rand authorized service technician.
http://air.irco.com

TROUBLE SHOOTING

REMEDY
§
Check incoming power supply.
§
Check the control circuit fuse.
§
Check the transformer secondary windings for the
control voltage.
§
Change Star / Delta timer.
Top up coolant.
§
Set overload to correct value and switch to manual
reset.
Change belt.
§
Ensure voltage does not drop below 10% on start up
and 6% running.
Set pressure to correct rating for machine.
Change air filter, and separator cartridge.
§
Ensure voltage does not drop below 10% on start up
and 6% running.
Correct incoming supply voltage.
Change Airend.
Change air filter.
Set pressure to correct rating for machine.
Reduce site voltage to correct operating voltage.
Fit inlet valve service kit.
Replace or set pressure to correct rating for machine.
Fit load solenoid service kit.
Fit blowdown solenoid service kit.
Fit inlet valve service kit.
Fit new Separator cartridge.
Set pressure to correct rating for machine.
Fit Minimum pressure valve service kit.
Fit load solenoid service kit.
Fit blowdown solenoid service kit.
Fit new belt and tensioner.
Fix leaks.
Fit inlet valve service kit.
Reduce demand or install additional compressor.
SSR UP6 15, UP6 20, UP6 25, UP6 30
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssr up6 20Ssr up6 25Ssr up6 30