Ingersoll-Rand SS3 Owner's Manual

Ingersoll-Rand SS3 Owner's Manual

Ingersoll-rand stationary air compressors owner's manual
Hide thumbs Also See for SS3:

Advertisement

ingersoll
Owner's
Manual
Installation, Operation and Maintenance
Instructions for Models SS3 and SS5
Stationary Air Compressors
IMPORTANT
INFORMATION!
READ
AND FOLLOW
THESE
INSTRUCTIONS.
RETAIN
FOR REFERENCE.
ll_*-]r-1 =1 ul li"
DEFINITIONS
/k_
WILL cause DEATH, SEVERE INJURY or substantial
property damage
WARNING
CAN cause DEATH, SEVERE INJURY or substantiaI
property damage,
CAUTION
WILL or CAN cause MINOR INJURY or property
damage.
GENERAL
SAFETY
PRECAUTIONS
,_ _
iNTAKE AIR, Can contain carbon monoxide
or other
contaminants. Will cause serious injury or death
ingersoll-Rand air compressors are not designed,
intended or approved for breathing
air Compressed
air should not be used for breathing air applications
unless treated in accordance
with all applicable
codes and regulaUons,,
WARNING
HAZARDOUS VOLTAGE Can cause serious injury
or death. Disconnect power and bteed pressure
from tank before servicing Lockout/Tagout
machine. Compressor must be connected to
properly grounded circuit See grounding
instructions
in manuat, Do not operate compressor
tn wet conditions,, Store indoors
MOVING PARTS, Can cause serious injury Do not
operate with guards removed. Machine may start
automatically
Disconnect power before servicing_
Lockout/Tagout machine,,
HOT SURFACES, Can cause serious
injury,
r
DO not
touch Allow to cool before servicing Do not touch
hot compressor or tubing
HIGH PRESSURE AIR. Bypassing_ modifying or
removing safety/relief valves can cause serious
injury or death, Do not bypass, modify or remove
safety/relief valves Do not direct air stream at body.
Rusted tanks can cause explosion and severe injury
or death Drain tank daily or after each use. Drain
valve located at bottom of tank.
z_ CAUTION
RISK OF BURSTING. Use only suitable air handling
parts acceptable for pressure of not less than the
maximum allowable working pressure of the
machine.
Your air compressor
unit is suitable for operating air too_s, caulking
guns, grease guns, sandblasters,
etc Depending on your
application,
the following accessories
may be required:
@ An air pressure regulator
to adjust the alr pressure enlering the
toot or accessory
An air line fitter for removal of moisiure and oil vapor in
compressed
air
An in-line lubricator to prolong lhe life of air tools.
ql, Separate air transformers which combine the !'unctions of air
regulation andlor moisture and dirt removal
Cenlact your nearest authorized
dealer or cal! 1-800-AIR-SERV
for
more information on air toots and accesser}as for your application
Ensure adequate lifting equipment
is available
for unloading and
moving your unit to the inslaIlatton
site
NOTE:
Lifting equipment must be property rated for the
weight of the unit.
Lift the unit by the shipping skid only,, Use straps to
prevent tipping
Lk CAUTION
Do not work on or walk under the compressor
while
it is suspended,
-...........
Be[ore signing the delivery receipl, i nspecl for damage and missing
parts
If damage or missing parts are apparenL
make the
appropriate
notation on the delivery receipt, then sign the receipt.
Immediately
contact the carrier for an inspection. All material must
be held in the receiving
location for the carrier's inspection Deiivery
receipts that have been signed without a notation of damage or
missing parts are considered
to be delivered "clear"
Subsequent
claims are then considered
to be concealed damage claims
SeUle
damage claims directly with the transportation
company
Lf you discover damage after receiving the unit (concealed
damage), the carrier must be notified within 15 days of receipt and
an inspection
must be requested
by telephone with confirmation
in
writing
On concealed
damage claims, the burden of establishing
that the unit was damaged in transit reverts back to the claimant
Read lhe unit specification
labei to verify it is the mode! ordered.
and read the meier nameplate to verify il is compatibJe with your
e_ectrical conditions
Make sure electrical
enclosures
and
componenls
are appropriate
for your applicafion
© IngersolL-Rand Company
Form SCD-B77A
Printed in U S A
March 2002

Advertisement

Table of Contents
loading

Summary of Contents for Ingersoll-Rand SS3

  • Page 1 © IngersolL-Rand Company Printed in U S A Installation, Operation and Maintenance Instructions for Models SS3 and SS5 READ AND FOLLOW THESE INSTRUCTIONS. Your air compressor...
  • Page 2: Installation

    SELECTING A LOCATION GENERAL° Select a clean, dry, welt-lighted of space far proper cooling air flow and accessibility. at least 12 inches (30 cm) from wails, and make sure the main power supply is clearly identified and accessible TEMPERATURE.. Ideal operating temperatures and 100°F (0°C and 37.B_C) If temperatures below 32°F (0"C), locale the unit inside a heated building not possible, you must protect safety!relief...
  • Page 3: Single-Phase Wiring

    Slowly flit the crankcase with lubricant until the lubricant reaches the top thread of the sit filI opening and the top of the sight glass Crankcase capacity for the SS3 Is one-half (0 5) Iiter Crankcase capacity for the SS5 is one (1) liter.,...
  • Page 4: Normal Start-Up

    A commercially spreader or other belt tensioning device can also be helpS'u1should tensioning be necessary, (SS3) The air intake holes in the baffle and cover must be staggered t80 _. When reinstalling the assembly...
  • Page 5 Ihe level of matntaoanCer The exact effect of these factors on lank life is difficult to predict; therefore, Ingersoll-Rand recommends that you schedule a certified tank inspection within the first five years of compressor arrange a tank inspection, conlacl the nearest _-R Air Center or...
  • Page 6: Troubleshooting

    :(0] II :| II:l"l_'[*Ia]l d I_ [{glm PROBLEM POSSIBLE CAUSE Abnormal piston, ring or Lubricant viscosity too tow cylinder wear Lubricant level too law Detergent type lubricant Cylinder(s) or piston(s) Extremely Worn cylinder finish Air delivery drops off Ctogged or dirty inlet and/or discharge Atr leaks tn air discharge Lubricant viscosity...
  • Page 7: Troubleshooting

    POSSIBLE CAUSE PROBLEM Knocking or retlting Loose beltwheel motor shaft Compressor Carbon build-up Cylindei'{s} Connecting scored Defective ball bearings er_ crankshaft or motor shaft Lights flicker or dim when Improper ttne voltage running Wiring or electric service panel too small Poor contact on motor terminals or starter connections lmproperstarterovedoad Poor power regulation (unbalanced...
  • Page 8 The foregoing warranty period shall apply to all EquipmenL Compressors that are operated solely on Ingersoll-Rand the earlier of twenty-four (24) months from the date of initial operation or thirty (30) months from the date of shipment...
  • Page 9: Parts List

    INGERSOLL-RANDo AIR COMPRESSORS PARTS LIST FOR MODEL BARE COMPRESSOR PUMP 25-- 31 _| @ Ingersoll-Rand Company Printed in U S A LISTA DE PIEZAS PARA MODELO BOMBA COMPRESORA ACCESORIOS Piston R}ng S_quenc_ Se_encla S_quence des segments Ingersoll-Rand Company 800-B Beery Street...
  • Page 10 REF NO PART NO N_ DE REF. N_ DE PIEZA DESCRIPTION N= DE REP. N" DE PIECE REF, 97334148 PUMP, BARE COMPRESSOR 20102703 SET, PISTON RING e RING, COMPRESSION • RING, SCRAPER • RIND, OiL CONTROL SPACER • RIND, OIL CONTROL 95033593 PLUG.
  • Page 11: Models Ss5L5 And Ss5N5 Parts List

    ingersoliRand 23.2.5 - 22.24 " " ... iTq--_,-', REF NO PART NO DESCRIPTION 84G03724 CAPSCREW 95750394 WASHER, SPRING LOCK 9733.148 PUMP. BARE COMPRESSOR ASSEMBLY, COMPLETE _188518 BRACE, BELTGUARD 56280159 SCREW, HEX _ SERRATED MS-1.0 X 12MM 54416730 BELTGUARD. FRONT 5441574_ BELTGUARD.
  • Page 12 START-UP KIT Each slart_Up kit contI31n._enough Ingersoll-Rand synthetic compressor _ubricant _nd _Ir ISlet etem_nts tD starbup and mglnfaln your _,8 fo_"lh_ first y_at PART NO DESCRIPTION 20100251 KIT. START*UP INGERSOLL-RAND SYNTHETIC COMPRESSOR LUBRICANT PART NO, DESCRIPTION 3231867,5 LUBRICANT, 1 QUART BOTTLE...

This manual is also suitable for:

Ss5Ss5n5Ss5l5

Table of Contents