Selection Of Circuit Protector And Contactor; Selection Of Circuit Protector - Mitsubishi Electric MDS-D-SPJ3 Specification Manual

Table of Contents

Advertisement

MITSUBISHI CNC
6 Specifications of Peripheral Devices

6-2 Selection of circuit protector and contactor

Always select the circuit protector and contactor properly, and install them to each drive unit to prevent disasters.

6-2-1 Selection of circuit protector

Calculate a circuit protector selection current from the rated output and the nominal input voltage of the drive unit
as in the expression below. And then select the minimum capacity circuit protector whose rated current meets the
circuit protector selection current.
Circuit protector selection current [A] =
(Circuit protector selection current for 200V input [A] / Nominal input voltage [V]) × 200 [V]
Unit type
MDS-D-SVJ3-
Rated output
Circuit protector selection
current for 200V input
Selection example of circuit protector
(Mitsubishi Electric Corp.)
Rated current of the selection example of
circuit protector
Unit type
MDS-D-SPJ3-
Rated output
Circuit protector selection current for
200V input
Selection example of circuit protector
(Mitsubishi Electric Corp.)
Rated current of the selection example of
circuit protector
Option part: A circuit protector is not prepared as an NC unit accessory, so purchase the part from your
dealer, etc.
1. It is dangerous to share a circuit protector for multiple drive units, so do not share it. Always install
the circuit protectors for each drive unit.
CAUTION
2. If the control power (L11, L21) must be protected, select according to the section "6-4-1 Circuit
protector ".
6 - 4
Selection of circuit protector for 200V input
03NA
04NA
0.3kW
0.4kW
2.5A
5A
NF30-
NF30-
SW3P-5A
SW3P-10A
5A
10A
075NA
22NA
0.75kW
2.2kW
6A
9A
NF30-
NF30-
SW3P-15A
SW3P-20A
15A
20A
07NA
10NA
20NA
0.75kW
1.0kW
2.0kW
7A
8A
10A
NF30-
NF30-
NF30-
SW3P-15A
SW3P-15A
SW3P-20A
15A
15A
20A
37NA
55NA
75NA
3.7kW
5.5kW
7.5kW
15A
23A
31A
NF30-
NF50-
NF100-
SW3P-30A
SW3P-50A
SW3P-60A
30A
50A
60A
35NA
3.5kW
15A
NF30-
SW3P-30A
30A
110NA
11kW
45A
NF100-
SW3P-
100A
100A

Hide quick links: