Appendix 1-2 Cable Connection Diagram; Appendix 1-2-1 Battery Cable - Mitsubishi Electric MDS-D-SPJ3 Specification Manual

Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Cable and Connector Specifications

Appendix 1-2 Cable connection diagram

1. Take care not to mistake the connection when manufacturing the detector cable. Failure to observe
this could lead to faults, runaway or fire.
CAUTION
2. When manufacturing the cable, do not connect anything to pins which have no description.

Appendix 1-2-1 Battery cable

<DG22 cable connection diagram (Connection cable between drive unit and drive unit)>
<DG23 cable connection diagram (Connection cable between drive unit and MDS-BTBOX-36)>
<DG24 cable connection diagram
(Connection cable for alarm output between drive unit and MDS-BTBOX-36)>
<DG25 cable connection diagram (Connection cable between drive unit and MDS-BTBOX-36)>
Appendix 1 - 4
Drive unit side connector
(Hirose Electric)
Connector: DF1B-2S-2.5R
Contact: DF1B-2428SCA
BT
1
LG
2
Drive unit side connector
(Hirose Electric)
Connector
: DF1B-2S-2.5R
Contact
: DF1B-2428SCA
BT
1
LG
2
Drive unit side connector
(3M)
Connector
:10120-3000VE
Shell kit
:10320-52F0-008
20
DICOM
D11
13
4
P5
1
LG
Case
FG
grounding
Drive unit side connector
(Hirose Electric)
Connector
: DF3-2S-2C
Contact
: DF3-2428SCC
BT
1
LG
2
Drive unit side connector
(Hirose Electric)
Connector: DF1B-2S-2.5R
Contact: DF1B-2428SCA
BT
1
2
0.2mm
2
LG
Battery box side
BT
2
0.2mm
LG
Battery box side
2
0.2mm
+24V
(DC power)
DO(ALM)
2
0.2mm
+5V
2
0.2mm
LG
Battery box side
BT
2
0.2mm
LG