Deflection Measurement Start (4000-series) (Sequence No. 435 (Hex
01B3))
This sequence starts a deflection measurement.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
• The deflection measurement keeps measuring until sequence No. 438 (Measurement Termi-
nation) is executed.
• This sequence will be processed the same as sequence No. 411 Zero run measurement start
for 5000-series Laser Micrometers.
Continuous Measurement Start (Scan) (4000-series)
(Sequence No. 436 (Hex 01B4))
This sequence starts a continuous measurement. The scan notification method is used for the receive
data.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
The receive data word allocation is similar to that of sequence No. 434 (Single Run Measurement
Start).
Additional Information
• Since this sequence repeats itself within the sequence, once it is executed, it remains in the
execution state until cancelled.
• Even if execution is cancelled, the Laser Micrometer still keeps measuring. Execute sequence
No. 438 (Measurement Termination) to end the sequence.
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
A Standard System Protocol
R-111