Siemens CP 1243-7 LTE Operating Instructions Manual page 115

Simatic net
Table of Contents

Advertisement

"Telecontrol server"
In STEP 7, the corresponding data is located in the "Partner stations" parameter area.".
This field is only used when the telecontrol server is addressed with a name that can be
resolved by DNS or when the IP address is to stored as a string.
Table 5- 5
IF_CONF_TCS_Name
Parameter
Id
Length
Mode
TcsName
RemotePort
Rank
"SMSC"
In STEP 7, the corresponding data can be found in the parameter area "Mobile wireless
communications settings" > "Services and settings".
Table 5- 6
IF_CONF_SMS_Provider
Parameter
Id
Length
Mode
SMSProvider
"PIN"
In STEP 7, the PIN can be found in the parameter area "Mobile wireless communications
settings" > "Services and settings".
Table 5- 7
IF_CONF_PIN
Parameter
Id
Length
Mode
Pin
CP 1243-7 LTE
Operating Instructions, 04/2017, C79000-G8976-C381-03
Data type
Initial value
UINT
6
UINT
UINT
-
-
STRING [254]
UINT
UINT
Data type
Initial value
UINT
10
UINT
UINT
STRING [20]
Data type
Initial value
UINT
11
UINT
UINT
STRING [8]
5.4 IF_CONF: SDT for the configuration data of the CP
Description
ID of the parameter field
Length of the parameter field in bytes: 266
Validity (1, 2) - see above (general parameters)
- reserved -
Name of the telecontrol server that can be resolved by
DNS or IP address as string
Port of the telecontrol server
Priority of the server [1, 2]
1 = first telecontrol server,
2 = second telecontrol server (second server not relevant)
Description
ID of the parameter field
Length of the parameter field in bytes: 28
Validity (1, 2) - see above (general parameters)
Subscriber number of the SMS center (SMSC) of the
mobile wireless network provider with which the mobile
wireless contract was signed for this station.
Description
ID of the parameter field
Length of the parameter field in bytes: 16
Validity (1, 2) - see above (general parameters)
PIN of the SIM card inserted in the SIM card
The parameter is not relevant if the PIN was correctly
configured. If the PIN was incorrectly configured, the
correct PIN can be entered.