4.11 Key Components Description
4.11.1 PCB
Part
Function
To control each component and also to check the overall performance of the unit.
Failure Event
Malfunctioning PCB.
A component may not operate within the unit and could produce an error code. In most cases of PCB failure, the
Effects
whole unit will not operate until the problem is resolved.
Error Code
E515, E615
Diagnostic
Visual inspection: Connection and/or breakage of wires and/or burn marks on the PCB.
Color/Number
of wires
58
NPE Service Manual
Check Point
25 (see page 40)
Version 2.21