Navien NPE-180A Service Manual page 163

Npe series condensing water heaters
Hide thumbs Also See for NPE-180A:
Table of Contents

Advertisement

2-Stage Thermostat / 2-Stage Control System
Set DIP switch (SW) #3 to 'On' to configure the system to use a
2-stage thermostat / 2-stage control.
10.3.2 Cable Connections
Follow the instructions below to connect the cables to the H2Air+
Connecting the Outdoor Temperature Sensor
Cable
An outdoor temperature sensor is supplied with the Navien
H2Air+
installation kit. Insert the exposed wire into the terminal.
+
Then tighten the terminal screw with a screwdriver.
NOTE
Use thermostat wire (18 gauge wire) for the outdoor
temperature sensor connection.
When installing the outdoor temperature sensor, avoid
installing it in direct sunlight.
162
NPE Service Manual
Connecting the Thermostat Cables
The H2Air+
receives input signals from thermostats to control the
+
AHU. Insert the fork connector into the contact. Then tighten the
terminal screw with a screwdriver.
Connecting the Flow Switch Cables
.
+
Insert the fork connector into the contact. Then tighten the
terminal screw with a screwdriver.
Version 2.21