Pcidevices Section; Systemeventlog Section - Cisco C880 M5 Configuration Manual

Hide thumbs Also See for C880 M5:
Table of Contents

Advertisement

6.2.3.11

PCIDevices section

The iRMC does not have any direct access to PCI data and therefore can only report
a limited subset on information. This information is based on what the server BIOS
has sent with the F119 OEM IPMI cmd and which can be retrieved with the F11A
OEM IPMI cmd.
<pcidevices schema="1">
<Device>
<ConfigSpace>
<Revision>1</Revision>
<VendorId>1000</VendorId>
<SubVendorId>1734</SubVendorId>
<DeviceId>005D</DeviceId>
<SubDeviceId>1212</SubDeviceId>
<BaseClass>Mass storage controller</BaseClass>
<SubClass>RAID controller</SubClass>
</ConfigSpace>
<Slot>17</Slot>
</Device>
</PCIDevices>
6.2.3.12

SystemEventLog section

The information generated is compliant with the CDiagReport.h implementation.
<SystemEventlog Schema="1">
<Entry>
<Date>2017/07/03 10:21:13</Date>
<Severity>Info</Severity>
<ErrorCode>37003A</ErrorCode>
<Message><![CDATA[System status - OS running]></Message>
<Data Size="14">
<HexDump Lines="1" BytesPerLine="14">
<Line Offset="0">
<Hex> 02 52 7F EE 59 20 00 04 F3 FE 73 25 FF 80 </Hex>
</Line>
</HexDump>
</Data>
</Entry>
Cisco C880 M5 Configuration Guide
6.2 iRMC system report
85