3.2 LUBRICATION GUIDE

Refer to Figure
3-1
best value and longest uninterrupted service, the
120 and 160 Series compressors are factory filled
and tested with Sullube lubricant as standard fill.
Mixing of other lubricants within the compressor
unit will void all warranties
If fluid change is required, follow Lubrication Guide
3.4 below.
"The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in exposed
plant piping." (I)
Sullube should not be used with PVC piping sys-
tems. It may affect the bond at cemented joints.
Certain other plastic materials may also be affect-
ed.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
For light-duty high-humidity service where con-
densed moisture and emulsification (mayonnaise)
may occur, the fluid change interval must be
reduced to 300 hours maximum. A non-detergent
fluid with rust, oxidation and foam inhibitors and
good water separation characteristics should be
16
For latest sound test data, consult Sullair Factory.
for fluid fill port location. For
STANDARD MODELS
40, 50, 60, 75 and 100HP/ 37, 45, 56 and 75 KW
C-Flanged, Open Dripproof, Premium Efficiency
Three Phase, 230/460 60 Hz, 380-415(400) 50 Hz
40°C Maximum Ambient Temperature
Options Available: 200V and 575V
T.E.F.C. Also Available: CE Approved
Full Voltage Magnetic, Wye Delta or Solid State
Options Available: 200V and 575V 60 Hz, 220 50 Hz
1780 RPM (60 Hz) or 1475 RPM (50 Hz)
1775 RPM (60 Hz) or 1475 RPM (50 Hz)
3560 RPM (60 Hz) or 2945 (50 Hz)
1780 RPM (60 Hz) or 2945 (50 Hz)
used.
DO NOT MIX DIFFERENT TYPES OF FLUIDS.
Contamination of non-detergent mineral fluids with
traces of detergent motor fluids may lead to opera-