Samsung CLX-9350ND Service Manual page 470

Digital color laser mfp
Hide thumbs Also See for CLX-9350ND:
Table of Contents

Advertisement

● Code :
U1-2132
U1-2135
● Symptom / Cause :
y
▶ U1-2132(Center), U1-2135 (Side)
1. FSA error
2. At warm up, the fuser temperature has not reached
● Troubleshooting method :
1. Turn the machine off and turn it on again.
2. Check the following :
A. Check the power voltage of the fuser unit. (110V, 2
B. Check if the Heat lamp is broken.
C Check if the AC connection of Heat lamp is discon
C. Check if the AC connection of Heat lamp is discon
D. Check if the drawer latches have been correctly p
E. Check if the thermostat is blown
F. Check if there is any jammed paper in fuser unit.
G. Check if the resistance value of NC sensor is norm
H. Check if the power voltage is normal. (Is the voltag
voltage?)
3. If the problem persists, replace the fuser unit.
4. If the problem persists after replacing the fuser unit,
board or SMPS.
● Replacement part
- JC91-00931A : FUSER (220V)
- JC91-00930A : FUSER (110V)
- JC92-02129A : PBA-ENGINE (CLX-9350ND)
- JC92-02239A : PBA-ENGINE (CLX-9250ND)
Service Manual
CLX-9250/9350 series
7. Troubles
shooting
● Error message :
Fuser Unit Failure #
U1-2132 : Turn off then on
Fuser Unit Failure #
U1-2135 : Turn off then on
its normal temperature within the regular time.
220V)
nnected or contaminated
nnected or contaminated.
ulled back.
mal.
ge during the operation ±10% of the rated
, replace the engine board or fuser control
7-1
30
SAMSUNG ELECTRONICS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clx-9250nd

Table of Contents