12
5.1

CONNECTING AUGER TUBE TO MAIN UNIT

Place fl anged end of auger
tube over the bolts of fl ange
located on the left side of the
main unit. Secure using the
washers & nuts provided. See
the fi gure on the right.
5.2
HOPPER BOTTOM CLOSING / OPENING SLIDE COVER
Slide the metal plate into its place directly below the fl ange. Make sure "square
holed section" of metal plate aligns with fl ange. (This is to lock and close the
fuel drop when auger is removed in case of repair or maintenance).
5.3
CONNECTING GEARBOX TO AUGER TUBE
Place the auger through the tube and connect the
screws on the fl ange.
W415-0771 / B / 08.10.09