Error Codes For Stop F On 840C - Siemens Sinumerik 840C Diagnostics Manual

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

1 Alarms
1.5.1 Alarm description
Table:

Error codes for STOP F on 840C

No.
Name
0
No error
1
Result list 1
2
Result list 2
3
Actual position value
4
No cross–comparison
5
Function enables
6
Limit value for SG1
7
Limit value for SG2
8
Limit value for SG3
9
Limit value for SG4
10
Standstill tolerance
11
Upper limit SE1
12
Lower limit SE1
13
Upper limit SE2
14
Lower limit SE2
15
Safe cam 1+
(+ Tolerance)
16
Safe cam 1+
17
Safe cam 1–
(+ Tolerance)
18
Safe cam 1–
19
Safe cam 2+
(+ Tolerance)
20
Safe cam 2+
21
Safe cam 2–
(+ Tolerance)
22
Safe cam 2–
23
Safe cam 3+
(+ Tolerance)
24
Safe cam 3+
25
Safe cam 3–
(+ Tolerance)
26
Safe cam 3–
27
Safe cam 4+
(+ Tolerance)
28
Safe cam 4+
29
Safe cam 4–
(+ Tolerance)
30
Safe cam 4–
31
Position tolerance
32
Reference position tolerance
33
Time/velocity switchover
34
Tolerance time/ SGE switch-
over
1–76
Explanation
There is no error in this channel, however an error
may have occurred in another channel.
Differences in the evaluation of the safe standstill/
safe speed/safe end position functions in the NCK
and drive monitoring channel
Differences in the evaluation of the SN function in
the NCK and drive monitoring channel
The difference between the actual position value in
the NCK and drive monitoring channel is greater
than the actual value cross–comparison tolerance
specified in MD 4256* or MD 1342
MD 4500*, 4504* and MD 1301 are not identical
MD 4184* and MD 1331 are not identical
MD 4188* and MD 1331 are not identical
MD 4192* and MD 1331 are not identical
MD 4196* and MD 1331 are not identical
MD 4180* and MD 1330 are not identical
MD 4200* and MD 1334 are not identical
MD 4208* and MD 1335 are not identical
MD 4204* and MD 1334 are not identical
MD 4212* and MD 1335 are not identical
MD 4216* + MD 4248* and MD 1336 + MD 1340
are not identical
MD 4216* and MD 1336 are not identical
MD 4232* + MD 4248* and MD 1337 + MD 1340
are not identical
MD 4232* and MD 1337 are not identical
MD 4220* + MD 4248* and MD 1336 + MD 1340
are not identical
MD 4220* and MD 1336 are not identical
MD 4236* + MD 4248* and MD 1337 + MD 1340
are not identical
MD 4236* and MD 1337 are not identical
MD 4224* + MD 4248* and MD 1336 + MD 1340
are not identical
MD 4224* and MD 1336 are not identical
MD 4240* + MD 4248* and MD 1337 + MD 1340
are not identical
MD 4240* and MD 1337 are not identical
MD 4228* + MD 4248* and MD 1336 + MD 1340
are not identical
MD 4228* and MD 1336 are not identical
MD 4244* + MD 4248* and MD 1337 + MD 1340
are not identical
MD 4244* and MD 1337 are not identical
MD 4256* and MD 1342 are not identical
MD 4252* and MD 1344 are not identical
MD 4264* and MD 1351 are not identical
MD 4260* and MD 1350 are not identical
Siemens AG 2001 All rights reserved 6FC5198–jAB40
Cause, Remedy
Find the cause in the other chan-
nel and interpret the error code
e.g. through unbalanced activa-
tion of the functions via the SGEs
Check the tolerance of the cams
Incorrect encoder evaluation
(check MDs)
different standstill positions stored
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
Enter the same MD values
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce