04/96
PLC machine
7. The machine data test is performed in the code restart branch.
data test
8. If the machine data are invalid, the group error number 110D (6EH) is transfer-
9. Detailed error identifiers
Address
F0000 F0001
0
Reserved
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
PLC MD for error and operational messages (channel-specific) set
8
PLC MD for error and operational messages (spindle-specific) set
9
PLC MD for error and operational messages (axis-specific) set
10
PLC MD for M decoding with extended addresses set. At least one decoding list is
missing.
11
PLC MD "1st machine control panel" set – input missing
6E
12
PLC MD "2nd machine control panel" set – input missing
13
Reserved
14
Reserved
15
PLC MD "1st machine control panel" set – output missing
16
PLC MD "2nd machine control panel" set – output missing
17
Reserved
18
Reserved
19
PLC MD for error and operational messages (DB58) set
20
Reserved
21
Reserved
22
Reserved
23
Reserved
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
2.2 Additional error information (ACCU 3 low byte, DB 1 DW 161–163)
red in the error field (address F0000 with programmer, cell FEHLCOD for sy-
stem program). The detailed error identifiers for each test are entered in the
additional error field (address F0001 with programmer, cell EADOPAD + 1 for
system program).
2 Diagnostics on the PLC
Error
2–13