Immunity - Ericsson CME 20 R6.1 Reference Manual

Table of Contents

Advertisement

EMC Capabilities for RBS 2302
The field strength of radiated emissions does not exceed the limits in
the following table at 3 m distance:
Table 55
Frequency of emission (MHz)
30 - 88
88 - 216
216 - 960
>960
Specification references:
Code of Federal Regulations 47, FCC part 15 chapter 15.33, 15.109
40.4

Immunity

Note:
40.4.1
Conducted Immunity on AC power ports
Fast Transient Test: RBS
Table 56
Product standard
Basic standard
Test level
Performance
Note:
Fast Transient Test: PBC
Table 57
Generic standard
Basic standard
Mandatory test level
Performance
Note:
270 (306)
Field strength of radiated emissions limits
Increased test level, extended frequency range and more
severe performance criteria are specified by Ericsson
internal EMC document.
Fulfills the EEC type approval certification requirements according to:
prETS 300 342-3, October 1997
EN 61 000-4-4, 1995
2 kV common mode between all lines and cabinet ground
reference.
Criteria TT
Criteria TR
see note 40.4
Fulfills the EEC self certification requirements according to:
EN 50 082-1, 1992
IEC 801-4, 1988
1 kV common mode between all lines and cabinet ground
reference.
Criteria B
see note 40.4
© Ericsson Radio Systems AB
— All Rights Reserved —
Field strength
(uV/m)
(dBuV/m)
100
40
150
43.5
200
46
500
54
EN/LZT 123 2697
R5A