Selection Of Installation Location; Indoor Unit; Outdoor Unit - Mitsubishi SRK13YJV-S Technical Manual & Parts List

Residential air-conditioning
Table of Contents

Advertisement

Standard accessories
(Installation kit)
Accessories for indoor unit
Installation board
1
(Attached to the rear of the indoor unit)
Wireless remote control
2
Remote contorol holder
3
Tapping screws
4
(for installation board 4dia. by 25mm)
Wood screw
5
(for remote contorol switch holder 3.5dia. by 16mm)
Baterry [R03 (AAA, Micro) 1.5V]
6
Air-cleaning filters
7
Filter holders
8
(Attached to the front panel of the indoor unit)
Option parts
Sealing plate
a
Sleeve
b
Inclination plate
c
Putty
d
Drain hose (extention hose)
e
Piping cover (for insulation of
f

Selection of installation location

INDOOR UNIT

1 Where there is no obstructions to the air flow and where the
cooled air can be evenly distributed.
2 A solid place where the unit or the wall will not vibrate.
3 A place where there will be enough space for servicing. (Where
space mentioned right can be secured)
4 Where wiring and the piping work will be easy to conduct.
5 The place where receiving part is not exposed to the direct rays
of the sun or the strong rays of the street lighting.
6 A place where it can be easily drained.
7 A place separated at least 1m away from the television or the
radio.
(To prevent interfence to images and sounds.)

OUTDOOR UNIT

1 A place where good air circulation can be obtained and where rain,
snow or sunshine will not directly strike the unit.
2 A place where discharged hot air or unit's operating sound will not
be a nuisance to the neighborhood.
3 A place where servicing space can be secured.
4 A place where vibration will not be enlarged.
*Avoid installing in the following places.
A place near the bedroom and the like, so that the operation
noise will cause no trouble.
A place where there is possibility of flammable gas leakage.
A place exposed to strong wind.
5 Blowing out port and suction port on the back side of the unit can
be installed at a distance of 10cm from walls.
(
In case the barrier is 1.2m or above in height, or is overhead, the
sufficient space between the unit and wall shall be secured.
6 When the unit is installed, the space of the following dimension
and above shall be secured.
RMA012A032_Installation.p65
Q'ty
1
1
1
5
2
2
2
2
Q'ty
1
1
1
1
1
1
connection piping)
28
Necessary tools for the installation work
1
Plus headed driver (Phillips screwdriver)
2
Knife
3
Saw
4
Tape measure
5
Hammer
6
Spanner wrench
(
7
Torque wrench
8
Hole core drill (65mm in diameter)
9
Wrench key (Hexagon) [4m/m]
10
Vacuum pump
Vacuum pump adapter
11
(Anti-reverse flow type)
(
12
Gauge manifold
(
13
Change hose
(
14
Flaring tool set
(
15
Gas leak detector
Gauge for projection adjustment (Used when flare
16
is made by using conventional flare tool)
17
Pipe bender
Left
side
5 cm
10 cm
MIN
Air
intake
Note
(1) If the wall is higher than 1.2 m or a ceiling is
)
– 28 –

-
-
04/05/2010, 17:28
)
14.0 ~ 62.0N · m
(1.4 ~ 6.2kgf · m)
(
)
Designed specifically
for R410A
)
Designed specifically
for R410A
)
Designed specifically
for R410A
)
Designed specifically
for R410A
)
Designed specifically
for R410A
Air intake
10 cm MIN
No obstacles
(Service space
for electrical
parts)
Air outlet
60 cm MIN
present, distances larger than indicated in the
above table must be provided.
Right
side
10 cm