Note (1) The number of flashes when in the Service Mode do not include the 1.5 second period when the lights light up at first (starting signal). (See the example
shown below.)
ON
RUN light
(10's digit)
OFF
ON
TIMER light
(1's digit)
OFF
Notes
(2) Abnormal Stop:
- Is not displayed. (automatic recovery only)
○ Displayed.
If there is a (
reached the number of times in (
If no (
Notes
(3) Automatic Recovery: - Does not occur
○ Automatic recovery occurs.
(d) Remote controller information tables
1) Operation switching
Display pattern when
in service mode
RUN light
(Operation switching)
0
1
2
3
4
* If no data are recorded (error code is normal), the information display in the remote controller becomes as follows.
Remote controller setting
Operation switching
Fan speed switching
(Example): Operation switching, fan speed switching, cooling HI
ON
RUN light
(10's digit)
OFF
ON
TIMER light
(1's digit)
OFF
• In the case of current safe (heating CT1) (example: stop code "32")
The RUN light (10's digit) flashes 3 times and the TIMER light (1's digit) flashes 2 times.
3 × 10 + 2 × 1 = 32 → From the table, read the instructions for error code 32, "Current safe (heating CT1).
1.5 sec.
0.5 sec.
0.5 sec.
) displayed, the error display shows the number of times that an automatic recovery occurred for the same reason has
).
) is displayed, the error display shows that the trouble has occurred once.