Blizzard 760HD Installation Instructions & Owner's Manual page 15

Snowplows
Hide thumbs Also See for 760HD:
Table of Contents

Advertisement

7.
Assemble the manifold. The manifold, pump
and coil harness have been connected at the
factory; however, the manifold contains several
components that you will need to install prior to
securing the assembly to the A-frame. Each of the
hose ports on the manifold is covered with stretch
wrap. Remove the wrap and install the appropriate
fi tting in its respective port. Tighten fi ttings and
hoses per torque chart.
1
NOTE: The arrows shown on the manifold
illustration indicate the direction the 90° adapters
should be positioned to receive the hydraulic
hoses.
NOTE: DO NOT let any foreign objects enter
into the open ports. The valves can become
contaminated and greatly hinder the snowplow's
performance. Torque to proper specifi cations.
NOTE: All ports are identifi ed by a stamped
number on the manifold. The numbers also
identify the hydraulic functions, which can be
referenced on the label under the hydraulic pump
and manifold cover.
Lit. No. B64090, Rev. 07
MOLDBOARD & A-FRAME ASSEMBLY
2
3
4
8. Align the mount holes in the pump with the holes
in the hinged bracket, located on the A-frame.
NOTE: Before mounting the pump, angle the
hinged bracket as needed and tighten the bracket
hardware to lock it in place.
Secure with 3/8" x 3/4" cap screw and 3/8" fl at
washer through the top mount hole in the bracket
and into the pump. Insert 3/8" x 1-3/4" threaded
stud with 3/8" locknut through the bottom mount
hole in the bracket and into the pump. The
threaded stud should bottom out in the pump.
NOTE: When installing the manifold between the
mount brackets on the A-frame, hold the manifold
at the sides of the block. Never handle the
manifold by coils. Doing so can cause a solenoid
cartridge to bend, causing the cartridge to stick
when activated.
NOTE: A medium strength thread-locking
compound should be used on both of the pump
mount fasteners.
9. Connect the hydraulic hoses to their respective
adapters on the manifold. Hose PN B60091
Ports #1 and #2, Hose PN B60273 Port #3 and
Hose PN B60274 Port #4. Tighten hoses per
torque chart.
NOTE: Both lift cylinder hoses should be routed
through the triangular openings in the A-frame.
Position these hoses over the A-frame angle and
to their respective manifold ports.
15
June 15, 2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

760lt800hd860hd

Table of Contents