Upper Looper Position To The Left Needle - Singer 14T957DC Service Manual

Serger overlock
Hide thumbs Also See for 14T957DC:
Table of Contents

Advertisement

9. Upper looper position to the left needle

Check:
1. Turn the handwheel in the normal direction until the upper looper is at its most left position.
2. The distance between upper looper point to the left needle "A" must now be 4.6 mm (B).
Setting:
1. Turn the handwheel in the normal direction until the upper looper is at its most left position.
2. Slightly loosen fastening screw (C) .
3. Move the upper looper arm until the distance between the upper looper point and the left
needle "A" is 4.6 mm (B).
4. Tighten fastening screw (C).
5. Re-check as described under "Check".
B
12
1047306-26

Advertisement

Table of Contents
loading

This manual is also suitable for:

14t967dc14t968dc professional 5