Max Model Setup
2. Press the ENTER button to lock in the
selection. The next MM number field to
the right flashes indicating it is ready for
programming.
3. Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second MM number
field.
4. Press the ENTER button to lock in the
selection.
The next number field to the right
flashes and the LED lights under SS; indicating it is
ready to program the seconds fields.
5. Repeat steps 1 - 4 to set the SS (seconds) fields.
6. After pressing the ENTER button to set
the last SS field, all the programmed ON
Time information is saved.
The G3 automatically switches to the OFF Time
SETUP MODE.

PUMP OFF / REST Setup

After setting the parameters for either Cycle (C1, C2 or
C3) or Pressure (P1, P2, or P3) ON modes, the OFF or
pump rest cycle must be set up. There are 3 ways to
control this function:
Machine Count switch activation, or
Machine Count activations limited by a maxi-
mum Time, or
A specific set amount of Time (similar to Time
Mode).
If the machine count sensor input is available
and not used in the OFF Mode, the definition of
the entered time is OFF TIME.
Machine Count
1. After you set the last ON Time field
and press the ENTER button, the G3
automatically switches to the
Machine Count setup.
Notice the LED next to 123 on the G3 display lights
34
indicating you are now in the Machine Count setup
mode.
2. Press the UP or DOWN
ARROW button to move up
or down through number 0-9.
3. When the correct number displays,
press the ENTER button to set the num-
ber.
NOTE: If the machine count input is available on the unit
and not used, the value MUST be set to zero (0).
4. Repeat 2 - 3 to set the remaining fields.
NOTE: After the Machine Count value is entered, the
G3 can be programmed to backup the machine count
input with time.
Backup Time Setup
1. The OFF Time LED lights.
OFF displays.
2. Press the UP or DOWN
ARROW button to change
OFF to ON on the display.
3. Press the ENTER button to set the
selection.
Backup Time
The LED next to the clock in the OFF
field lights, indicating you are setting
the Backup Time parameters.
OFF Time is set in Hours and Minutes
(HH: MM).