Electrical Data - Lennox XP25-024-230-01 Installation And Service Procedure

Dave lennox signature collection xp25 series units
Table of Contents

Advertisement

Electrical Data

Maximum
Over-
Model Number
current
Protection
(amps)
XP25-024-230-01
25
Maximum
Over-
Model Number
current
Protection
(amps)
XP25-036-230-01
25
Maximum
Over-
Model Number
current
Protection
(amps)
XP25-048-230-01
40
Maximum
Over-
Model Number
current
Protection
(amps)
XP25-060-230-01
40
1
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
Unit
Compressor
Rated
Locked
Minimum
Load
Rotor
Circuity
Amps
Amps
2
Ampacity
(RLA)
(LRA)
1
15.7
10.30
18.00
Unit
Compressor
Rated
Locked
Minimum
Load
Rotor
Circuity
Amps
Amps
2
Ampacity
(RLA)
(LRA)
1
20.3
14.00
18.00
Unit
Compressor
Rated
Locked
Minimum
Load
Rotor
Circuity
Amps
Amps
2
Ampacity
(RLA)
(LRA)
1
33.7
24.70
29.00
Unit
Compressor
Rated
Locked
Minimum
Load
Rotor
Circuity
Amps
Amps
2
Ampacity
(RLA)
(LRA)
1
34.9
25.70
29.00
208/230V-60 Hz-1 Ph
Outdoor Fan (RPM varies with compressor RPM)
CFM
Motor
HP
MAX
MIN
1/3
2580
1845
208/230V-60 Hz-1 Ph
Outdoor Fan (RPM varies with compressor RPM)
CFM
Motor
HP
MAX
MIN
1/3
4130
1865
208/230V-60 Hz-1 Ph
Outdoor Fan (RPM varies with compressor RPM)
CFM
Motor
HP
MAX
MIN
1/3
4040
3315
208/230V-60 Hz-1 Ph
Outdoor Fan (RPM varies with compressor RPM)
CFM
Motor
HP
MAX
MIN
1/3
4240
3025
Page 3
RPM
WATTS
MAX
MIN
MAX
723
515
70
RPM
WATTS
MAX
MIN
MAX
850
390
214
RPM
WATTS
MAX
MIN
MAX
805
658
172
RPM
WATTS
MAX
MIN
MAX
845
600
198
Full
Load
Amps
MIN
(FLA)
32
2.80
Full
Load
Amps
MIN
(FLA)
40
2.80
Full
Load
Amps
MIN
(FLA)
98
2.80
Full
Load
Amps
MIN
(FLA)
76
2.80
XP25