LG FMN0760NL Service Manual page 92

Free joint multi type
Table of Contents

Advertisement

I The problem of missing the connector (OUTDOOR MAIN PCB ASSY)
Connectors
CN-POWER
CN-AC
CN-DC
CN-IPM
CN-GND1, 2
CN-HEATER
CN-4WAY
CN-FAN 1, 2
CN-TH 1~6
CN-PWR
I The problem of missing the connector (SUB PCB ASSY)
Connectors
CN-UVW
CN-IPM
CN-GATE 1, 2
Condition
• Malfunctions outdoor unit.
OPEN
• Stop compressor and outdoor fan.
• The operation LED02T blinks 5 times.
• Malfunctions outdoor unit.
OPEN
• Stop compressor and outdoor fan.
• The operation LED02T blinks 8 times.
• Malfunctions outdoor unit.
OPEN
• Stop compressor and outdoor fan.
• The operation LED02T blinks 10 times.
• Malfunctions inverter circuit.
OPEN
• Stop compressor and outdoor fan.
• The operation LED02T blinks 9 times.
OPEN
• Malfunctions EMI / EMS
OPEN
• Malfunctions Sump Heater
• Malfunctions 4-WAY valve.
OPEN
• Malfunctions fan.
OPEN
OPEN/SHORT
• The LED02T blinks twice.
OPEN
• The LED02T blinks 11 times.
Condition
• Stop compressor.
OPEN
• Malfunctions inverter circuit.
OPEN
• Stop compressor and outdoor fan.
• Malfunctions inverter circuit.
OPEN
• Stop compressor and outdoor fan.
-92-
Problem (error mode)
Problem (error mode)

Hide quick links: