Self-diagnosis Function

I Error Indicator
• The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.
• Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
• If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.
• After error occurrence, if error is released, error LED is also released simultaneously.
• To operate again on the occurrence of error code 15, be sure to pull out power cord and then re-insert.
• Having or not of error code is different from Model.
ERROR
CONTENTS
CODE
Indoor
Thermistor
1
open/short
Outdoor
Thermistor
2
open/short
Wired Remocon
3
Communication
Error
Drain pump
4
Error
Poor
5
Communication
Fire alarm
6
Response
Difference
7
Operation
CT Current
8
9
IBM Error
DC
10
Low Voltage
High Voltage/Power
Error/Condenser
11
Temp. Error
Connecting Wire/
12
Pipe Error
Excessive
13
Capacity
Discharge Temp.
14
Error
Incorrect Wiring
15
(U.V.W)
LED DISPLAY
- 29 -
NO DISPLAY
OPERATION
CASE
• Stop the indoor Fan
Operation
When indoor thermistor
OFF
is error.
• Operates by Outdoor
Operation
OFF
Micom Control.
• Operation ON
• Stop the operation
• Signal on For
5 Seconds
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above
Same as
Same as above
above

Hide quick links: