LG FMN0760NL Service Manual page 91

Free joint multi type
Table of Contents

Advertisement

I The problem of missing the connector (INDOOR MAIN PCB ASSY)
Connectors
CN-POWER
(AC2)
CN-FAN
CN-DATA
CN-DISP1
CN-TH
CN-U/D
Condition
OPEN
OPEN
OPEN
OPEN
OPEN/SHORT
OPEN
Problem (error mode)
• Malfunctions all indoor & outdoor unit.
• Malfunctions remocon, force, test operation mode.
• Malfunctions indoor fan motor.
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan motor.
• The operation LED blinks 5 times.
• Communicaion error.
• Malfunctions remote contoller.
• Don't operate the power display module.
• The operation LED blinks once.
• Enable to receive remote singnal.
• Malfunctions UP/DOWN step motor.
• Don't operate louver.