GAS INLET
The gas connection is made at the underside of the water heater. The pipe work must be cleared of foreign
matter before connection and purged before attempting to operate the water heater. An isolation valve and
disconnection union must be installed to allow servicing and removal of the water heater (refer to the
on page
20).
Note: Refer to the Gas Installations Standard AS 5601 or AS/NZS 5601.1 for the correct method of sizing the
gas supply pipe to the water heater. The pipe size selection must take into account the high gas input of this
water heater
(refer to table on page 18)
Warning: Always isolate the water heater before pressure testing the gas supply system. Disconnect the
water heater after the isolation valve to prevent the risk of serious damage to the gas control. The Rheem
warranty does not cover damage of any nature resulting from failure to observe this precaution. Refer to rating
label for gas types and pressures.
FLAME
ROD
TO CHASSIS
/ GAS VALVE
PILOT GAS
VALVE
SV1
TO CHASSIS
( INTERNALLY CONNECTED
TO GAS VALVE )
COLOUR CODE
R : RED
W : WHITE
BR : BROWN
BK : BLACK
GR : GREEN
O : ORANGE
Y : YELLOW
as well as all of the other gas appliances in the premises.

WIRING DIAGRAM

WIRING DIAGRAM
IGNITER
ELECTRODE
BK
BK
S
IGNITION
MODULE
1 2 3 4 5 6 7 8
O
W W
R BK
W V
G
WATER
HYDRO-
THROTTLING
ELECTRIC
GENERATOR
VALVE
Wiring Diagram – 834 Series Water Heater
ON
DIP
1 2 3 4 5 6 7 8
DIP SWITCH SETTING
STATE
SW 1
SW 2
ON
OFF
OFF
OFF
SW 4
SW 5
STATE
I / D
12 L
ON
16 L
OFF
O / D
SW 7
OFF
OFF
ON
SW 8
OFF
ON
ON
SET TEMP
45
50
60
OVER TEMPERATURE
CUT OUT SWITCH
WATER
R
R
FLOW
SENSOR
O
O
BK
BK
SV2
GR
GR
O
SV3
R
BK
TO CHASSIS ( INTERNALLY
CONNECTED TO GAS VALVE )
ON
1 2 3 4 5 6 7 8
Min
Max
16
15
14
13
12
11
10
9
8
FAULT
ON
7
6
5
4
(RED )
(GREEN)
3
2
1
4
3
TEMPERATURE
2
1
CONTROLLER
# REPLACEMENT BATTERY IS
AVAILABLE FROM RHEEM SERVICE
21
CONNECTIONS – PLUMBING
diagram
SW 3
OFF
SW 6
PROPANE
NATURAL
ON
OFF
60
OUTLET HW
THERMISTOR
MAIN GAS
VALVE
MASV GAS
VALVE
DIP
DC 3.7V
Rechargeable
Battery Only #
_
+
SK7691 6/15 REV AD