Field Setting Mode - Samsung AE090JNYDEH User Manual

Split/tdm plus hydro unit
Hide thumbs Also See for AE090JNYDEH:
Table of Contents

Advertisement

Field setting mode

Field Setting Value (FSV) Table
NOTE
• Reset the power after changing the Field Setting Value.
Code 10∗∗ : U pper and lower temperature limits of each operation mode of wired remote controller
Heating(Water Out, Room), Cooling(Water Out, Room), DHW(Tank)
Code 20∗∗ : W ater law design and external room thermostat Heating(2 WL's for floor & FCU),
Cooling(2 WL's for floor & FCU), WL & Thermostat types
Main Menu &
Sub Menu Function
Code
Water Out Temp for Cooling
Room Temp for Cooling
Remote
Controller
Water Out Temp for Heating
Setting Range
Code 10∗∗
Room Temp for heating
DHW Tank Temp
Outdoor Temp for Water Law
Water Out Temp for WL1
Heating (WL1-Floor)
Water Out Temp for WL2
Heating (WL2-Fan Coil Unit)
Heating Water Law for Auto
Water Law
Code 20∗∗
Outdoor Temp for Water Law (Cooling)
Water Out Temp for WL1
Cooling (WL1-Floor)
Water Out Temp for WL2
Cooling (WL2-Fan Coil Unit)
Cooling Water Law for Auto Mode
External Thermostat
38
38
English
English
Field Setting Value
Description Sub Code Default
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Point
(Heating)
Point
Point
Point
Point
Point
WL Type
Mode
Point
Point
Point
Point
Point
Point
WL Type
#1 (Floor)
Application
#2 (FCU)
∗∗11
25
∗∗12
16
∗∗21
30
∗∗22
18
∗∗31
55
∗∗32
25
∗∗41
30
∗∗42
16
∗∗51
50
∗∗52
40
∗∗11
-10
1
∗∗12
15
2
∗∗21
40
1
∗∗22
25
2
∗∗31
50
1
∗∗32
35
2
∗∗41
1(WL1)
∗∗51
30
1
∗∗52
40
2
∗∗61
25
1
∗∗62
18
2
∗∗71
18
1
∗∗72
5
2
∗∗81
1(WL1)
∗∗91
0(No)
∗∗92
0(No)
Min
Max
Step
18
25
1
5
18
1
28
30
1
18
28
1
37
55
1
15
37
1
18
30
1
16
18
1
50
70
1
30
40
1
-20
5
1
10
20
1
17
55
1
17
55
1
17
55
1
17
55
1
1
2
-
25
35
1
35
45
1
5
25
1
5
25
1
5
25
1
5
25
1
1
2
-
0
2
1
0
2
1
Unit
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
˚C
-
˚C
˚C
˚C
˚C
˚C
˚C
-
-
-