6.5 COMMAND DESCRIPTION

About GET Command
A
Operation description of GET command
Conditions under which GET commands are enabled
Most of the GET commands are enabled at any time, regardless of unit's being on/off or in Factory or Normal mode. However, some GET
commands must be issued while the power is on to acquire correct data.
[Operations]
• Reading out and sending various data stored in the EEPROMs and the RAMs of microcomputers
• Adding a received string of command characters at the beginning of reply data as an echoback
• Decimal notation are converted into ASCII numerics and transmitted.
• CS is 2 bytes, to be interpreted as ASCII codes for 2 hexadecimal digits. These are the low-order 2 bytes of the total value of "receive
command + transmission data" (except STX and ETX).
Reply data format
B
STX
Example:
[02]
GST: GET STATUS
Order
1
Display data
2
Power data
3
Input function data (main)
C
4
Input function data (sub)
5
Screen size data
6
Two-screen indication
7
FUNCTIONAL LOCK data
8
Dummy data
9
Temperature data 2 (TEMP2)
D
10
Temperature data 3 (TEMP3)
11
Serial
12
Dummy data
13
Dummy data
14
HOUR METER data
15
Dummy data
Display data
1st character
2nd character
3rd character
Power data
E
1st character
2nd character
3rd character
Screen size data
1st character
Not.1: During Standby or immediately after the power is turned on, accurate temperature data cannot be obtained.
To obtain an accurate temperature reading, wait for a few minutes after the power is turned on.
F
Not.2: During Standby or full-screen display, dummy data (symbols) are output.
Not.3: During Standby or full-screen display, values stored in memory of the unit are output.
Not.4: See "3. SERIAL" on page 97 for details on the serial data.
114
1
2
Received
Transmission
command
data
(3byte)
GAS
2
Data
Data on generation: 4 (Fixation)
Data on screen size: 4 (43 inches), 5 (50 inches)
Data on destination: M (Fixation)
Power status and signal status
PN (power on & at usually, of signal Input), PL (power on & no input), PO (power on & out of
range signal Input), SN (stand by/ on), SW (power management standby), SS (SD and PD
standby),
Multi screen features. The sub signal state of a input (see Note. 2)
N (at usually, of signal Input), L(no Input), O (out of range in signal Input)
Numbers used are the same as those that indicate SIG-MODE screen sizes.
0: Dot by Dot PARTIAL, 1: 4:3, 2: FULL or FULL1080i, 3: ZOOM, 4: WIDE,
6: CINEMA, 8: FULL1035i, 9: UNDERSCAN
PDP-504CMX/1
2
3
Transmission
• • •
data
• • •
0
Size
3 byte
See the table below.
3 byte
See the table below. (The third character is for the subinput.)
Input data during GST reception (INPUTs 1 to 5 are indicated as
3 byte
IN 1-5.)
Subinput data during GST reception (INPUTs 1 to 5 are indicated
3 byte
as IS 1-5.)
1 byte
See the table below.
0: OFF (Full-screen) 1: 2-SCREEN
1 byte
3: PinP (Upper right) 4: PinP (Upper left) 5: PinP (Lower left)
6: PoutP
0: LOCK OFF
1 byte
3: IR&BUTTONS LOCK 4: MEMORY LOCK
3 byte
(Three-digit figure)
°C (Not.1)
3 byte
°C (Not.2)
3 byte
15 byte
(Νοτ.4)
3 byte
(Three-digit figure)
3 byte
5 byte
Indicated in hours
2 byte
(Checksum)
3
4
CS (2byte)
ETX
97
[03]
Remarks
2: PinP (Lower right)
1: BUTTONS LOCK 2: IR LOCK
4