Stanley MC521 Pro Installation And Operation Manual page 11

Includes instructions for: duraglide 2000/3000, 5200/5300, duraguard, and durastorm automatic slide door systems
Table of Contents

Advertisement

Index
Min.
Max.
Value
Value
00
05
35
01
05
18
02
03
10
03
10
99
04
10
99
05
00
99
06
01
99
07
00
01
08
00
75
09
00
75
10
00
75
11
00
01
12
00
01
13
01
60
14
20
60
15
20
60
16
20
60
17
20
60
18
00
02
19
00
04
© 2010, THE STANLEY WORKS. ALL RIGHTS RESERVED.
Table 3. Settings
Open speed, increment by 1.
Close speed, revolutions per second.
Check speed, revolutions per second.
Open check length, percent of full opening.
Close check length, percent of full opening.
Reduced open position, percent of full opening (00=full open,
99=full close).
Hold open delay (0 to 25 sec.).
Lock Logic, 01 = Fail Secure, 00 = Fail Safe Note: For locks with
circuit board, set to 01 Fail Secure. For locks with no circuit
board, set to Fail Safe or Fail Secure.
Open torque, percent of full scale.
Close torque, percent of full scale.
Check torque, percent of full scale.
Dura-Glide function switch type: 00=double pole rotary,
01=rocker
2S Operation, 0=off, 1=on
Obstruction Time Delay (.01 – 1.5 sec) Heavy and dual motor
doors may require a longer obstruction time (45 on buttons or 1.2
sec. on Palm).
Open Acceleration, (larger value=faster acceleration).
Open Braking, (larger value=increased braking).
20=No open braking
Close Acceleration, (larger value=faster acceleration).
Close Braking, (larger value=increased braking).
20=No close braking
00 = Off (Delay Egress)
01 = 15 sec. delay
02 = 30 sec delay
00 = Standard Monitor
01 = StanVision Monitor
02 = Wizard Monitor
03 = Active Eight Monitor
04 = Standard No Monitor
Description
Defaults
Single
25
12
04
35
30
50
03
01
25
25
25
01
00
12
50
54
20
40
00
04
204066
Rev. A, 11/23/10
10 of 27
Dual
25
12
04
35
30
50
03
01
25
15
10
01
00
40
50
54
20
40
00
04