FIG. 8
Thermocouple
Thermocouple
connection
F.
No bubble should appear at the opening of the
burner jet. Bubbles indicate a defective gas safety
shutoff and service is required.
G.
If no bubbles were present at the burner jet, rinse
the orifice with water. Replace the burner cover
plate. Start the refrigerator by following the
instructions for gas operation with piezo ignitor. See
Section B. Operating Instructions, Item 3, Gas
Operation.
Normal gas operation should occur. Allow the
burner to operate for a minimum of five (5) minutes.
WARNING
DO NOT USE A FLAME TO CHECK
FOR GAS LEAKS.
Clear Blue Color of Flame
Spring
n
Refrigerators with Automatic Reignitors
(RM2510, RM2610 & RM2810)
A.
Start the refrigerator according to the instructions
for Gas Operation with Automatic Reignitor. See
Section B. Operation Instructions, Item 3, Gas
Operation.
Check that the gas flame is lit and the lamp 'E' is
B.
out. (See FIG. 9).
5
Thermocouple
9
FIG.
RM2610
RM2810
RM2510