SECTION C. MAINTENANCE AND SERVICE

1. PERIODIC MAINTENANCE

To keep your Dometic refrigerator operating efficiently
and safely, period inspection and cleaning of several
components is recommended once or twice a year.
A.
It is important to keep the area at the back of the
refrigerator clear. Check the lower vent, upper vent
and the area between these openings for any
obstructions such as bird/insect nests, spider webs,
etc. It is important to keep the refrigerator area free
from combustible material, gasoline and other
flammable liquids or vapors.
B.
Check all connections in the LP gas system (at the
back of the refrigerator) for gas leaks. The LP gas
supply must be turned on. Apply a non-corrosive
bubble solution to all LP gas connections.
WARNING
DO NOT USE A FLAME TO CHECK
FOR GAS LEAKS.
C. Check burner flame for proper appearance. The
flame should be light blue with no yellow at the tip.
(See FIG. 16).
FIG. 16
FIG. 17
Thermocouple \
connection
Spring
TEST
PORT
The following maintenance is required once
or twice a year, but should only be done by
a qualified serviceman who is familiar with LP
gas systems and refrigerators.
CHECKGASPRESSURE
D.
The LP gas pressure should be checked and
readjusted if necessary. The correct operating
pressure is eleven inches of water column. The
correct place to take the pressure reading is at the
test port just ahead of the main orifice. (See FIG.
17.)
CLEANING FLUE TUBE, BURNER & BURNER JET
E.
NOTE:
Before working on the refrigerator make
sure that 120 volt AC and optional 12 volt
DC leads are disconnected. Shut off Gas
valve.
The Burner and the Burner Jet:
The color of the flame should be clear blue over the
slots of the burner. (See FIG. 16).
Once or twice a year, depending on use, clean
and adjust the burner assembly.
Proceed as follows:
1.
Remove protection plate from the burner
housing.
2.
Disconnect the wire from the high voltage
electrode.
3.
Remove the burner mounting screws and
remove the burner assembly.
4.
Clean burner tube with a brush. Blow with
compressed air.
5.
Remove the burner jet. Soak the jet in wood
alcohol and blow it out with compressed air.
NEVER use a wire or pin to clean the burner
jet.