12 | Regulation

3.8 Fault diagnosis

To identify possible faults refer to Chapter 8.
CAUTION:
▶ In the area of the burner, the front may
reach high temperatures with a risk of
burns in the event of contact.
DANGER: Explosion!
The installation, maintenance and repair
should only be carried out by an accredited
company Bosch.
▶ See the table 8 to find solutions for possible
problems (solutions followed by * should
only be carried out by an accredited
company Bosch).
4
Regulation
The appliance comply with local standards.
5
Installation (only by qualified
technicians)
DANGER: Explosion
▶ Always close the gas shut-off valve before
carrying out any work in components that
conduct gas.
The installation, the electrical connection, the
gas installation, the installation of the flue/
intake duct, as well as the first start-up are
operations that should be carried out
exclusively by a company from the Authorized
Service Bosch.
The appliance may only be used in the
countries indicated on the rating plate.

5.1 Important information

▶ Before carrying out the installation, consult the gas supply
company and the local norms in force.
▶ Fix a gas shut-off valve as close as possible to the appliance.
6 720 818 788 (2015/11)
▶ After completion of the gas network, thorough cleaning
must be done and a tightness test carried out to avoid
damage due to excess pressure in the gas valve.
This has to be carried out with the gas valve of the appliance
closed.
▶ Check if the appliance to be installed matches the type of
gas supplied.
▶ Check if the flow and pressure supplied by the gas regulator
installed are as indicated for the consumption of the
appliance (technical data in the table 6);
Heater installed with LPG gas - Pay attention to the
maximum volume consumed by the heater, as the number of
cylinders should match the consumption. In the event of the
number of cylinders being minor than the consumption of
the heater, the water may not heat and the gas may freeze,
making the formation of olein possible which damages the
internal parts of the appliance.

5.2 Choice of installation site

Provisions regarding the installation site
• Do not install the appliance in rooms with a volume less than
3
8 m
(do not consider the volume of the furnishings, as this
3
does not exceed 2 m
).
• Comply with the specific determinations of each country.
• Install the heater in a well ventilated site, away from negative
temperatures, where there is a combustion gas duct.
• The heater may not be installed on a heat source.
• To avoid corrosion it is necessary for the combustion air to
be free from aggressive substances. An example of
particularly corrosive materials are halogen hydrocarbons
present in solvents, paints, glues, motor gases and various
domestic detergents. If necessary, take the proper
measures to correct the conditions.
• Respect the minimum installation measures indicated in
Fig. 12.
If there is a risk of freezing:
▶ Switch the appliance off,
▶ Take out the batteries,
▶ Bleed the appliance ( section 3.6).