Wiring Connection - LG LM-4462C2T Service Manual

Ceiling cassette multi
Table of Contents

Advertisement

5. Wiring Connection

• Open the control box cover and connect the Remote controller cord and Indoor power wires.
Indoor
power cord
Remote
controller
cord
LM-4462H2T
A-Unit
Terminal Block of Indoor Unit
3(L) 4(N)
5
6
LM-4462C2T
A-Unit
Terminal Block of Indoor Unit
3(L) 4(N)
5
6
The power cord connected to the outdoor unit should be complied
with the following specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer or its service agent.
WARNING
Make sure that the screws of the terminal are free from looseness.
B-Unit
Terminal Block of Indoor Unit
7
3(L) 4(N)
5
6
7
B-Unit
Terminal Block of Indoor Unit
7
3(L) 4(N)
5
6
7
NORMAL
CROSS-SECTIONAL
2
AREA 8.0mm
Control box cover
Control box cover
fitting screw(2 units)
Terminal Block of
Outdoor Unit
4(N)
3(L)
Power Cord
Terminal Block of
Outdoor Unit
3(L)
4(N) 3(L) 4(N) 5(A) 3(L) 4(N) 5(B)
Power Cord
CAUTION
The connecting cable connected to the indoor and outdoor unit
should be complied with the following specifications (Rubber
insulation, type H05RN-F approved by HAR or SAA).
–19–
[Air inlet side view]
Terminal Block of Outdoor Unit
6
5 4(N) 3(L) 5
6
Terminal Block of Outdoor Unit
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lm-4462h2t

Table of Contents