FEATURES AND CONTROLS
Instrument Cluster
Diagnostic Display Code Definitions
Component
Vehicle Speed Sensor
System Power
Engine Speed
ECU Memory
Calibration
Steering Over Current Shut Down
Steering Excessive Current Error
Steering Torque Partial Failure
Steering Torque Full Failure
60

Diagnostic Codes

Condition
EPS Models Only
Data Valid But Above Normal
Operational Range - Most
Severe Level
Data Erratic, Intermittent Or
Incorrect
Abnormal Rate Of Change
Received Network Data In Error
Data Valid But Above Normal
Operational Range - Most
Severe Level
Voltage Above Normal, Or
Shorted To High Source
Voltage Below Normal, Or
Shorted To Low Source
Data Valid But Above Normal
Operational Range - Most
Severe Level
Data Erratic, Intermittent Or
Incorrect
Received Network Data In Error
Bad Intelligent Device Or
Component
Out Of Calibration
Out Of Calibration
Current Above Normal Or
Grounded Circuit
Current Above Normal Or
Grounded Circuit
Condition Exists
Condition Exists
SPN
FMI
84
0
84
2
84
10
84
19
168
0
168
3
168
4
190
0
190
2
190
19
628
12
628
13
630
13
520221
6
520222
6
520223
31
520224
31